SEC-Light Scattering for Antibody Drug Conjugate Characterization
Wyatt Technology
Among the factors critical to effective ADC design is the drug antibody ratio (DAR). The DAR describes the degree of drug addition, which directly impacts both potency and potential toxicity of the therapeutic, and can have significant effects on properties such as stability and aggregation. Determination of DAR is, therefore, of critical importance in the development of novel ADC therapeutics. We present here a method for DAR determination based on SEC-MALS in conjunction with UV absorption and differential refractive index detection. Read More |
 |
Analysis of Membrane Protein by Multi-Detector SEC
Malvern Instruments
Detailed description of how a protein detergent complex (PDC), formed during the purification of a bacterial membrane protein involved in multidrug resistance, can be fully characterized. A triple detection SEC system, equipped with light scattering and viscometer detectors, was used to measure the molecular weight and composition of the PDC and of the free detergent micelles. Read More |
|
|
|
 |
Validation of PAHs in Soil and Sediment Samples Using Pressurized Liquid Extraction, Cleanup, and Concentration
Phillip Bassignani, FMS,Inc.
PAHs are a group of organic compounds consisting of two or more benzene rings and are often the byproduct of petroleum combustion. Due to their carcinogenic characteristics at relatively low concentra-tions, they are of particular environmental concern. Seven PAHs have been classified by the US EPA as probable human carcinogens and their toxic characteristics and persistent nature place them among the most extensively monitored organic contaminants. The following procedure details the use of pressurized liquid extraction (PLE) in conjunction with automated silica gel cleanup (PowerPrep) to deliver a robust, efficient sample prep process for soils and sediments designated for PAH analysis. Outlined, are an initial precision and recovery study (IPR), a matrix detection level study (MDL), and a matrix validation of a NIST reference material. Read More |
 |
Extraction of Mycotoxins from Grain using ISOLUTE® Myco prior to LC-MS/MS analysis
Adam Senior, Helen Lodder, Mats Leeman & Dr. Claire Desbrow, Biotage AB, Sweden
ISOLUTE Myco SPE columns provide robust, reliable sample preparation for multiple mycotoxin classes from a wide range of foodstuffs optimized for LC-MS/MS analysis. This application note describes the extraction of a range of relevant mycotoxins from grains (wheat, maize, barley), with high analyte recoveries, low RSDs and LOQs that meet regulatory requirements. Read More |
 |
Determination of Pesticides in Strawberries by QuEChERS Extraction, Quick QuEChERS Clean-up, and GC/MS Detection
Xiaoyan Wang, UCT, Inc.
Pesticides in strawberries and similar food products can be easily and more quickly extracted and analyzed using this modified QuEChERS application. Read More |
|
|
|
|
|
 |
Metabolic Profiling of Coffee
Dr. Verena Tellstrom, Dr. Alexander Harder, Klaus Meyer and Dr. Aiko Barsch, Bruker Daltonics
With worldwide consumption of coffee at 4.5 million tons, quality control is an important issue and can be established on a large scale through metabolomic profiling. In this study, 13 types of coffee capsule extracts were analyzed to correlate high resolution LC-MS data to the manufactuturer's description via a non-targeted metabolomics approach. Read More |
|
|
|
 |
Fast Determination of N-Methyl Carbamate Pesticides in Fruit and Vegetable Juice
Rong-jie Fu and Andrew Zhai, Agilent Technologies
A method for the determination of N-methyl carbamate pesticides in fruit and vegetable juices uses an Agilent 6460 Triple Quadrupole LC/MS with an Agilent Poroshell 120 Bonus-RP LC column. A sample prep method using Agilent Bond Elut QuEChERS is optimized to extract 10 pesticides in juice samples. Read More |
 |
Troubleshooting System Problems Using Waters Neutrals Quality Control Reference Materials
Kenneth D. Berthelette, Mia Summers, and Kenneth J. Fountain, Waters Corporation
In this application, six common chromatographic problems are examined to demonstrate the utility of the Neutrals QCRM in rapidly diagnosing problems on an HPLC or UPLC system. After repairs were made, the Neutrals QCRM was used to quickly confirm that the system was back to operating optimally. By using the Neutrals QCRM to check system functionality, data quality can be assured and the system can be used with confidence. Read More |
 |
Seamless Instrument-to-Instrument Method Transfer Using ISET
A.G. Huesgen, Agilent Technologies
The seamless method transfer of an USP method from the Agilent 1220 Infinity LC System to the Agilent 1290 Infinity Binary LC using the Agilent Intelligent System Emulation Technology (ISET) is shown. Read More |
|
|
|
|
|
|
|