Spectroscopy Webcast
TWO LIVE EVENTS
Europe: Wednesday, July 11, 2018 at 2pm BST | 3pm CEST
North America: Wednesday, July 11, 2018 at 11am EDT | 10am CDT | 8am PDT
Can’t make the live webcast? Register now and view it on-demand after the air date.
Click to register for this free webcast »
Event Overview
Conventional single quadrupole ICP-MS instruments with helium mode collision–reaction cells (CRCs) produce acceptable results in the vast majority of routine trace metal or elemental impurity measurements. But data quality can be compromised by the presence of more intense or problematic spectral interferences, especially in cases where low analyte levels combine with complex and variable sample types. In these cases, single quadrupole ICP-MS may be unable to identify or resolve the interferences, leading to uncertainty and errors.

The solution to these analytical challenges is to use a double mass selection approach, known as tandem MS or MS/MS, using a triple quadrupole ICP-MS instrument. MS/MS allows precise control of the interference removal process using reactive cell gases, giving reliable, accurate results for interfered elements. Controlled reaction chemistry simplifies ICP-MS methodology, as the reaction chemistry is independent of the sample matrix or the presence of other analytes. This means that the same analytical conditions can be applied to many different sample types, including those where the sample composition is not known in advance.

The benefits of ICP-QQQ with MS/MS have been widely accepted in industries where data quality is key, as well as proving invaluable in research applications. Now the need for greater certainty and improved data quality is leading to adoption of ICP-QQQ with MS/MS for more typical ICP-MS applications. In this webcast, we’ll discuss examples that explain why.
Key Learning Objectives
  • See how MS/MS can identify and resolve the hidden interferences that may be causing errors in your ICP-MS trace element data
  • Find out how method development tools unique to ICP-MS/MS can help you select the best cell gas and analyte product ions for your application
  • Understand how MS/MS can simplify your ICP-MS analysis, by allowing you to use consistent reaction methods for varied samples
  • Learn how triple quadrupole ICP-MS improves detection limits and allows access to elements not traditionally run on ICP-MS
Who Should Attend
  • Lab managers and analysts responsible for producing high quality data in trace-metal and elemental impurity labs will benefit from this webcast
  • If you need to understand and address the potential sources of error in your ICP-MS data, this is the event for you
Presenters
Bert Woods
ICP-MS Applications Chemist
Agilent Technologies
Laura Bush
Moderator
Laura Bush
Editorial Director
Spectroscopy
Sponsored by:
Presented by:
Spectroscopy
Click to register for this free webcast »
 
Have any questions? Contact Kristen Moore at kristen.moore@ubm.com
Subscribe: PrintDigitalEnews
FaceBook icon   Linked In icon